c) Installation work and electrical wiring must be done by a qualified person (s) in
accordance with all applicable codes and standards, including fire-rated construction.
d) When cutting or drilling into walls or ceilings, avoid damaging electrical wiring and other
hidden utilities.
e) Ducted fans must always be vented to the outdoors.
f) If this unit is to be installed over a tub or shower, it must be marked appropriately for the
application and be connected to a GFCI (Ground Fault Circuit Interrupter) protected
branch circuit.
g) NEVER place a switch where it can be reached from a tub or shower.
h) When used in an attic install exhaust side of the fan facing an unoccupied space.
i) This unit has an unguarded impeller. Do not use in locations readily accessible to people
or animals.
j) Sufficient air is needed for proper combustion and exhausting of gases through the flue
(chimney) of fuel burning equipment to prevent back drafting. Follow the heating
equipment manufacturer’s guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.